Split case pumps - ANDRITZ

Double-flow split case pump for applications with high-temperature media - ASPH series. The ANDRITZ ASPH pump is a double-flow, single-stage, axial split case pump, specially developed for the high strength and long lifetime requirements in district heating networks and for other applications with high-temperature media.

Double suction centrifugal split case pumps

Vertical single-stage centrifugal pumps, series: DPNL Horizontal single-stage centrifugal pumps, series: DPNT and DPNM Horizontal single-stage split case pumps, series: DPAS to which this declaration refers, are in accordance with the following standard: EN 809/A1 according to the provisions of the harmonized standard for pumps and which ...

HS horizontal split case pumps | Grundfos

The Grundfos HS horizontal split case pump is a single-stage, non-self-priming, between bearing, centrifugal volute pump. The axially split design allows easy removal of the top casing and access to the pump components (bearings, wear rings, impeller, and shaft seal) without disturbing the motor or …

China Horizontal Single Stage Double Suction Split Casing ...

Split Case Pump, Split Casing Pump, Water Pump manufacturer / supplier in China, offering Horizontal Single Stage Double Suction Split Casing (Case) Pump, Centrifugal Pump, Water Pump, High Flow Pump, Volute Casing Pump, Fire Fighting Pump, Electric Sewage Self Priming Slurry Trash Water Pump for Industrial, 12V/24V Micro Air Diaphragm Mini Water Pump with Electric Motor and so on.

Aurora 410 Series Single Stage Split Case Pumps Brochure

SINGLE STAGE SPLIT CASE PUMPS WWW.AURORAPUMP.COM MOdel 411 MOdel 413. 2 SINGle STAGe SPlIT CASe PUMPS VeRTICAl MOdel 413 ... design provides high efficiency and performance. C. Bronze Shaft Sleeve prevents shaft wear, ... FLOW (m3/hr) 1 10 100 1000 10000 12x14x15B 12 x 14x 18A 1 4x 1 6x1 8 10x12x18D 1 0x1 2x1 8 8x10x21 10 x 12x1 5B 8x10x17B 10 ...

Split-Case Pumps | Intro to Pumps

Most split-case pumps are axially-split – meaning that the flange at which the pump casing separates is in the same plane as the pump axis. Radially-split pumps are also available, and are commonly used in very high-pressure and high-temperature industrial applications (boiler-feed pumps are one common application for radially-split pumps).

China High Efficiency Single Stage Double Suction ...

Centrifugal Pump, Fire Pump, Multistage Pump manufacturer / supplier in China, offering High Efficiency Single Stage Double Suction, Centrifugal Pump, Dewatering Pump, Sea Water Pump, Fire Pump, Water Pump, Axially Split Case Pump, Convey Soda Liquid Rotary Lobe Pump Stainless Steel 316, High Quality Sanitary High Viscosity Pharmaceutical Rotary Lobe Pump and so on.

OPERATION & MAINTENANCE MANUAL for DOUBLE SUCTION …

This manual covers the installation, operation and maintenance of Patterson Pump horizontal split case pumps. The pump is a centrifugal, single stage, double suction type. When properly installed and when given reasonable care and maintenance, centrifugal pumps should …

OPERATION & MAINTENANCE MANUAL for DOUBLE SUCTION SPLIT …

This manual covers the installation, operation and maintenance of Patterson Pump horizontal split case pumps. The pump is a centrifugal, single stage, double suction type. When properly installed and when given reasonable care and maintenance, centrifugal pumps should …

Aurora 410 Series Single Stage Split Case Pumps Brochure

SINGLE STAGE SPLIT CASE PUMPS WWW.AURORAPUMP.COM MOdel 411 MOdel 413. 2 SINGle STAGe SPlIT CASe PUMPS VeRTICAl MOdel 413 ... design provides high efficiency and performance. C. Bronze Shaft Sleeve prevents shaft wear, ... FLOW (m3/hr) 1 10 100 1000 10000 12x14x15B 12 x 14x 18A 1 4x 1 6x1 8 10x12x18D 1 0x1 2x1 8 8x10x21 10 x 12x1 5B 8x10x17B 10 ...

Single Case Pumps - Axially Split - LR | Flowserve

Single Case Pumps - Axially Split - LR BRAND: Worthington With thousands of units installed over the years, these pumps provide reliable and efficient performance in applications ranging from water supply to circulation duties to petroleum distribution.

Single Stage Double Suction Split Case Pump - Changsha …

Single Stage Double Suction Split Case Pump. ... XS500-710 high efficiency split case pump... XS500-520 big flow split case pump... XS400-675 split case pump... XS400-560 single stage double suction centrifugal pump... XS350-630 high efficiency split case pump...

Split-Case Pumps | Intro to Pumps

Most split-case pumps are axially-split – meaning that the flange at which the pump casing separates is in the same plane as the pump axis. Radially-split pumps are also available, and are commonly used in very high-pressure and high-temperature industrial applications (boiler-feed pumps are one common application for radially-split pumps).

Pentair Fairbanks Nijhuis 1800 Series Single Stage Split ...

SINGLE STAGE SPLIT CASE PUMPS www.FairbanksNijhuis.com Model 1840 Model 1820 Model 1810. 2 SINGle STAGe SPlIT CASe PUMPS VeRTICAl Model ... design provides high efficiency and performance. C. Bronze Shaft Sleeve prevents shaft wear, ... FLOW (m3/hr) 1 10 100 1000 10000 12" 1823 B 1 4" 1 82 4 10" 1824D 1 0" 1 82 4 8" 1825 10" 1823 B 8" 1824B 10 ...

e-XC Single Stage, Double Suction Centrifugal Pumps ...

With more models and more material options, the e-XC single stage, double suction, centrifugal pump offers a broader hydraulic range and higher efficiency than our previous models. Built on a legacy of pump innovation, the e-XC replaces the AC Series 8100, 8300 and 9100 pump range.

Single Stage Double Suction - Xylem Applied Water …

Mixed Flow Pumps; SMVT – Surface Mount Vertical Turbine ... Home Centrifugal Pumps & Boosters Single Stage Double Suction. Share ... GL 512 G&L Series A-C 8100 – Split Case. G&L Pumps Series A-C 8300 – Split Case Pumps (GL-520) G&L Pumps Series A-C 9100 (GL-516) Refine Results. Search by keyword. Search by keyword. Centrifugal Pumps ...

HS horizontal split case pumps | Grundfos

The Grundfos HS horizontal split case pump is a single-stage, non-self-priming, between bearing, centrifugal volute pump. The axially split design allows easy removal of the top casing and access to the pump components (bearings, wear rings, impeller, and shaft seal) without disturbing the motor or …

Centrifugal pump - Wikipedia

Centrifugal pumps are used to transport fluids by the conversion of rotational kinetic energy to the hydrodynamic energy of the fluid flow. The rotational energy typically comes from an engine or electric motor. They are a sub-class of dynamic axisymmetric work-absorbing turbomachinery. The fluid enters the pump impeller along or near to the rotating axis and is accelerated by the impeller ...

Pentair Fairbanks Nijhuis 1800 Series Single Stage Split ...

SINGLE STAGE SPLIT CASE PUMPS www.FairbanksNijhuis.com Model 1840 Model 1820 Model 1810. 2 SINGle STAGe SPlIT CASe PUMPS VeRTICAl Model ... design provides high efficiency and performance. C. Bronze Shaft Sleeve prevents shaft wear, ... FLOW (m3/hr) 1 10 100 1000 10000 12" 1823 B 1 4" 1 82 4 10" 1824D 1 0" 1 82 4 8" 1825 10" 1823 B 8" 1824B 10 ...

Single Stage Double Suction Split Case Pump - Changsha …

Single Stage Double Suction Split Case Pump. ... XS500-710 high efficiency split case pump... XS500-520 big flow split case pump... XS400-675 split case pump... XS400-560 single stage double suction centrifugal pump... XS350-630 high efficiency split case pump...

G&L Pump A-C Series 8300 - Split Case Pumps - Xylem ...

Commercial Split Case Pumps G&L A-C Series 8300 & 8300RS Double-suction, base-mounted A-C Series 8300 pumps are available in 2” through 10” sizes. Motor sizes through 300 HP. Flows to 6500 GPM and heads to 400 feet. Bronze-fitted construction with a maximum working pressure of 175 psig. The G&L A-C Series 8300 features internally self-flushing mechanicalRead more

Split Case Pumps & Double Suction Split Casing …

If it is split vertically in relation to the impeller it is referred to as a vertical split case pump, and if it is split horizontally is it a horizontal split case pump. This design makes split case centrifugal pumps suitable for higher flow rate applications usually involving water and thin, low viscosity liquids at …

Single Stage Double Suction - Xylem Applied Water …

Mixed Flow Pumps; SMVT – Surface Mount Vertical Turbine ... Home Centrifugal Pumps & Boosters Single Stage Double Suction. Share ... GL 512 G&L Series A-C 8100 – Split Case. G&L Pumps Series A-C 8300 – Split Case Pumps (GL-520) G&L Pumps Series A-C 9100 (GL-516) Refine Results. Search by keyword. Search by keyword. Centrifugal Pumps ...

Split Case Pumps | SPP Pumps

Split case centrifugal pumps feature a single double suction or two single suction impellers supported between bearings. The casing is split axially, with opposing suction and discharge flanges, greatly simplifying maintenance.

Horizontal Split Case Pumps | Find info and get quotes

The pump has a split case design. - Single stage- Ruhrpumpen manufacturers its HSC, HSD, HSR, ZW pumps for the municipal, petrochemical, paper, pipeline applications and more. The HSC horizontal split centrifugal pump allows for 140,000 gpm and 550 feet of head. The HSD model is made with a high efficiency design. - Multistage – Ruhrpumpen ...

Centrifugal Pumps - an overview | ScienceDirect Topics

Radial flow pumps develop head by centrifugal force. Axial flow pumps, however, develop the head due to a propelling or lifting action of the impeller vanes on the liquid. Radial flow pumps are used when high heads are required, while the axial flow and mixed flow pumps are mainly used for low head–high capacity applications.

All Products | Flowserve

The DVSR is a between bearings, radially split, single stage pump designed for continuous service in severe duty, high pressure pipeline services. Based on our range of DVSH, axially split pumps with over 100 hydraulics available, the DVSR is the ideal choice where an axially split pump is limited.